冀北地区输电线路覆冰风险预报研究

王馨1,卢毅1,张旭1,杨琳晗2,武辉芹2   

  1. (1.国网冀北电力有限公司电力科学研究院,北京100045;
    2.河北省气象服务中心,河北石家庄050021)

  • 出版日期:2020-02-29 发布日期:2020-03-13
  • 基金资助:
    国家电网公司总部科技项目(52018K170028)资助

Research on Risk Forecast of Transmission Lines Icing in Northern Hebei Province

WANG Xin1, LU Yi1, ZHANG Xu1, YANG Linhan2, WU Huiqin2#br#

#br#
  

  1. (1. State Grid Jibei Electric Power Co.,Ltd., Research Institute, Beijing 100045, China;
    2. Hebei Provincial Meteorological Service Center, Shijiazhuang 050021, China)
  • Online:2020-02-29 Published:2020-03-13

摘要: 利用国网冀北电力部门提供的2012—2015年冀北地区输电线覆冰事故资料以及电力微气象站资料,对输电线覆冰事故进行时空分布特征分析,同时选定输电线覆冰事故发生当日的最低、最高气温,平均相对湿度,平均风速,降水量等气象要素作为因子,利用层次法构建输电线覆冰风险预报模型并进行个例验证。结果表明:冀北地区输电线覆冰事故多发于山区,主要集中在11月至次年5月;不同的覆冰事故类型对应的下垫面类型也各不相同,冰闪事故56%以上发生在平原和坝上高原,舞动主要分布于山地和山谷;大多数输电线覆冰发生时,日最低气温为-8~0 ℃,日最高气温为-4~4 ℃,日平均相对湿度在80%以上,日平均风速为1~3 m·s-1;实际发生输电线覆冰灾害时,覆冰风险预报等级均在2级以上,无漏报,但存在较小的空报率。

关键词: 电线覆冰, 风险, 层次分析法

Abstract: Based on the data of transmission line icing accidents in Northern Hebei  Province and power microweather station observations from 2012 to 2015 provided by the power company, the characteristics of spatial and temporal distribution of transmission line icing accidents were analyzed. Meanwhile, the daily minimum temperature, maximum temperature, average relative humidity, average wind speed and daily precipitation were selected as forecast factors. The risk prediction model for transmission line icing was built and verified. The results show that transmission line icing accidents mostly occurred in mountainous areas in Northern Hebei Province and mainly from November to May of the following year. Different types of underlying surfaces corresponded to different types of ice accidents. More than 56% of icing flashover occurred in plain and the plateau on bam, and dancing mainly distributed in mountains and valleys. Most accidents occurred when minimum daily temperature ranged from -8 to 0 ℃, the maximum daily temperature ranged from -4 to 4 ℃, the average daily relative humidity was above 80%, and the average daily wind speed ranged from 1 to 3 m·s-1. The test results of prediction model of transmission line icing accidents showed that when transmission line icing accidents happened, the prediction results were all above level 2, and there was no false negatives, but there was a small false alarm rate.



Key words: transmission line icing accidents, risk, hierarchical analysis method